Copyright
©The Author(s) 2023.
World J Clin Cases. Mar 16, 2023; 11(8): 1830-1836
Published online Mar 16, 2023. doi: 10.12998/wjcc.v11.i8.1830
Published online Mar 16, 2023. doi: 10.12998/wjcc.v11.i8.1830
Ensure that FiO2 = 1 | Already used, but unable to improve |
Check BB position with a fiberoptic bronchoscope | Already used, but unable to improve |
Ensure optimal cardiac output and reduce volatile anesthetics (< 1MAC) | Already used, but unable to improve |
Apply recruitment maneuver to the ventilated lung | Already used, but unable to improve |
Apply PEEP (5 cmH2O) to the ventilated lung | Already used, but unable to improve |
Perform intermittent re-expansion on the non-ventilated lung | Unable to apply |
Mechanically restrict blood flow of the non-ventilated lung | Unable to apply |
- Citation: Zhou C, Song S, Fu JF, Zhao XL, Liu HQ, Pei HS, Guo HB. Continuous positive airway pressure for treating hypoxemia due to pulmonary vein injury: A case report. World J Clin Cases 2023; 11(8): 1830-1836