Copyright
©The Author(s) 2023.
World J Clin Cases. Jul 16, 2023; 11(20): 4814-4823
Published online Jul 16, 2023. doi: 10.12998/wjcc.v11.i20.4814
Published online Jul 16, 2023. doi: 10.12998/wjcc.v11.i20.4814
120° fixed group | 125° fixed group | 130° fixed group | 135° fixed group | 140° fixed group | |
Maximum stress value (MPa) | 72.6 | 72.25 | 26.24 | 52.21 | 32.73 |
Maximum displacement (mm) | 7.446 | 7.416 | 7.324 | 8.138 | 8.246 |
- Citation: Wang Y, Ma JX, Bai HH, Lu B, Sun L, Jin HZ, Ma XL. Mechanical analysis of the femoral neck dynamic intersection system with different nail angles and clinical applications. World J Clin Cases 2023; 11(20): 4814-4823
- URL: https://www.wjgnet.com/2307-8960/full/v11/i20/4814.htm
- DOI: https://dx.doi.org/10.12998/wjcc.v11.i20.4814