Table 5 Sensitivity and specificity corresponding to each cutoff value of Huaxi Unplanned Extubation Risk Assessment Scale
CutoffSensitivity1-specificitySpecificityYouden indexa
10.00001.0001.00000
11.50001.0001.00000
12.50001.0000.9960.0040.004
13.50001.0000.9320.0680.068
14.50000.9620.7350.2650.227
15.50000.9620.6010.3990.361
16.50000.9230.4480.5520.475
17.50000.8850.3350.6650.55
18.50000.8850.2600.740.625
19.50000.8460.2190.7810.627
20.50000.8460.1860.8140.66
21.50000.7690.1570.8430.612
22.50000.6920.1220.8780.57
23.50000.5000.0930.9070.407
24.50000.3460.0660.9340.28
25.50000.1150.0450.9550.07
26.50000.0770.0320.9680.045
27.50000.0380.0180.9820.02
28.50000.0000.0070.993-0.007
29.50000.0000.0010.999-0.001
31.00000.0000.00010