Copyright
©The Author(s) 2022.
World J Clin Cases. Jul 16, 2022; 10(20): 6890-6899
Published online Jul 16, 2022. doi: 10.12998/wjcc.v10.i20.6890
Published online Jul 16, 2022. doi: 10.12998/wjcc.v10.i20.6890
EA (n = 57) | DPE (n = 58) | Z/t/χ2 | 95%CI of difference | P value | |
The onset time to T6 level (min) | 16.6 (15.8-17.4) | 14.7 (13.9-15.4) | 4.039 | -5.0, 0.0 | 0.0012 |
Maximum sensory level (T) | 5 (4-6) | 5 (4-5) | 1.120 | 0.0, 1.0 | 0.2632 |
Modified bromage score to 3, n (%) | 21 (36.8) | 45 (77.6) | 19.516 | 2.6, 13.5 | < 0.001 |
Cranial sensory block to T6, n (%) | 30 (52.6) | 54 (93.1) | 23.915 | 3.8, 38.0 | < 0.001 |
Vasopressor administration, n (%) | 6 (10.5) | 9 (15.5) | 0.631 | 0.5, 4.7 | 0.4273 |
Intraoperative IV analgesic supplementation, n (%) | 16 (28.1) | 7 (12.1) | 4.600 | 0.1, 0.9 | 0.0323 |
Local anesthetic volume (ml) | 20.0 (17.5-20.0) | 20.0 (15.0-20.0) | 0.429 | 0.0, 0.0 | 0.6682 |
Fluid administration (ml) | 800.0 (750.0-800.0) | 800.0 (700.0-800.0) | 0.806 | 0.0, 0.0 | 0.4242 |
Estimated blood loss (ml) | 400.0 (400.0-400.0) | 400.0 (300.0-400.0) | 1.548 | 0.0, 0.0 | 0.1222 |
Duration of surgery (min) | 37.4 ± 8.3 | 36.3 ± 6.3 | 0.746 | -3.7, 1.7 | 0.4571 |
Urine output (ml) | 100.0 (100.0-150.0) | 100.0 (100.0-150.0) | 0.248 | 0.0, 0.0 | 0.8042 |
Adverse effects, n (%) | |||||
Hypotension | 5 (8.8) | 2 (3.5) | 1.425 | 0.1, 2.0 | 0.4223 |
Respiratory depression | 0 (0.0) | 0 (0.0) | 0.000 | 0.0, 0.0 | 1.0003 |
Postdural headache | 0 (0.0) | 0 (0.0) | 0.000 | 0.0, 0.0 | 1.0003 |
Nausea and vomiting | 7 (12.3) | 5 (8.6) | 0.412 | 0.2, 2.3 | 0.5213 |
Chest distress | 5 (8.8) | 7 (12.1) | 0.334 | 0.4, 4.8 | 0.5633 |
Dizzy | 6 (10.5) | 4 (6.9) | 0.477 | 0.2, 2.4 | 0.7193 |
Nasal obstruction | 5 (8.8) | 6 (10.3) | 0.082 | 0.3, 4.2 | 0.7743 |
Chills | 19 (33.3) | 14 (24.1) | 1.188 | 0.3, 1.4 | 0.2763 |
Neonatal outcomes | |||||
Apgar score < 8 at 1 min, n (%) | 3 (5.3) | 2 (3.4) | 0.000 | 0.1, 4.0 | 0.9843 |
Apgar score < 8 at 5 min, n (%) | 0 (0.0) | 0 (0.0) | 0.000 | 0.0, 0.0 | 1.000 |
- Citation: Wang SY, He Y, Zhu HJ, Han B. Dural puncture epidural technique provides better anesthesia quality in repeat cesarean delivery than epidural technique: Randomized controlled study. World J Clin Cases 2022; 10(20): 6890-6899
- URL: https://www.wjgnet.com/2307-8960/full/v10/i20/6890.htm
- DOI: https://dx.doi.org/10.12998/wjcc.v10.i20.6890