Copyright
©The Author(s) 2022.
World J Clin Cases. Jan 14, 2022; 10(2): 502-510
Published online Jan 14, 2022. doi: 10.12998/wjcc.v10.i2.502
Published online Jan 14, 2022. doi: 10.12998/wjcc.v10.i2.502
Table 5 Comparison of surgical complication rates between the two groups, n (%)
Group | n | Incision infection | Delayed fracture union | Traumatic arthritis | Complication rate |
Study group | 49 | 1 | 0 | 1 | 2 (3.77) |
Control group | 48 | 4 | 1 | 3 | 8 (15.09) |
χ2 | 4.153 | ||||
P value | 0.042 |
- Citation: Li HF, Yu T, Zhu XF, Wang H, Zhang YQ. Locking compression plate + T-type steel plate for postoperative weight bearing and functional recovery in complex tibial plateau fractures. World J Clin Cases 2022; 10(2): 502-510
- URL: https://www.wjgnet.com/2307-8960/full/v10/i2/502.htm
- DOI: https://dx.doi.org/10.12998/wjcc.v10.i2.502