Copyright
©The Author(s) 2022.
World J Clin Cases. Jan 14, 2022; 10(2): 426-436
Published online Jan 14, 2022. doi: 10.12998/wjcc.v10.i2.426
Published online Jan 14, 2022. doi: 10.12998/wjcc.v10.i2.426
Indicator | Group | Time | Group × Time | |||
F value | P value | F value | P value | F value | P value | |
hs-CRP | 2.376 | 0.128 | 5.237 | 0.025 | 0.005 | 0.945 |
IL6 | 0.022 | 0.882 | 13.798 | < 0.001 | 0.787 | 0.378 |
CK-MB | 29.785 | < 0.001 | 10.998 | 0.001 | 1.429 | 0.236 |
D-dimer | 11.266 | 0.001 | 18.322 | < 0.001 | 2.926 | 0.092 |
- Citation: Lin L, Xue D, Chen JH, Wei QY, Huang ZH. Methylprednisolone accelerate chest computed tomography absorption in COVID-19: A three-centered retrospective case control study from China. World J Clin Cases 2022; 10(2): 426-436
- URL: https://www.wjgnet.com/2307-8960/full/v10/i2/426.htm
- DOI: https://dx.doi.org/10.12998/wjcc.v10.i2.426