Variable | 1st clearance study | 2nd clearance study | P value |
PD duration, mo | 9.2 ± 15.2 | 17.4 ± 15.8 | |
VU, L/24-h | 0.54 ± 0.63 | 0.40 ± 0.53 | < 0.001 |
VD, L/24-h | 11.3 ± 3.2 | 12.1 ± 3.6 | NS |
Kt/V urea, weekly | 2.30 ± 0.62 | 2.12 ± 0.03 | 0.003 |
CCr, L/1.73 m2, weekly | 77.9 ± 32.1 | 67.9 ± 18.2 | 0.002 |
SUN, mg/dL | 49.7 ± 15.1 | 49.4 ± 16.2 | NS |
[Cr]S, mg/dL | 9.1 ± 3.3 | 10.1 ± 3.4 | 0.001 |
EXCr U, mg/24-h | 406 ± 337 | 286 ± 350 | 0.003 |
EXCr D, mg/24-h | 680 ± 337 | 769 ± 390 | < 0.001 |
EXCr T, mg/24-h | 1087 ± 470 | 1055 ± 421 | NS |
- Citation: Xu Z, Murata GH, Sun Y, Glew RH, Qualls C, Vigil D, Servilla KS, Golper TA, Tzamaloukas AH. Reproducibility of serial creatinine excretion measurements in peritoneal dialysis. World J Nephrol 2017; 6(4): 201-208