Copyright
©The Author(s) 2015.
World J Virology. Nov 12, 2015; 4(4): 323-342
Published online Nov 12, 2015. doi: 10.5501/wjv.v4.i4.323
Published online Nov 12, 2015. doi: 10.5501/wjv.v4.i4.323
Technique | Advantages | Disadvantage | Commercial assays | Ref. |
RIA | High sensitivity | High cost | IRMA kit (North Institute of Biological Technology, Beijing, China) | [38,39,44] |
Risk to operator | ||||
EIA | Automation | Time consuming, need sophisticated equipment and trained technicians, continuous supply of electricity, not suitable for field settings | ETI-AB-AUK-3 (DiaSorin) | [41,42,47,48] |
High reproducible results | Enzygnost anti-HBs (Dade Behring) | |||
Low cost | Monolisa anti-HBs (Bio-Rad Laboratories) | |||
MEIA | High sensitivity | Sophisticated equipment, trained technicians, continuous supply of electricity | Abbott Axsym AUSAB assay | [47] |
Faster than other immunological methods | ||||
ECLIA | High sensitivity | High cost, sophisticated equipment, trained technicians, continuous supply of electricity | Modular E170 analyzer, Roche Diagnostics | [43,44,46] |
Results available in few minutes | ||||
Automation | ||||
CLIA | High sensitivity and specificity Automation | High cost, sophisticated equipment, trained technicians, continuous supply of electricity | Advia Centaur anti-HBs | [47] |
Vitros anti-HBs on the Vitros ECI Immunodiagnostic system (Ortho Clinical Diagnostics) | ||||
Roche Elecsys anti-HBs on the Modular System (Roche Diagnostics) | ||||
Liaison anti-HBs on the Liaison system (DiaSorin) Abbott Architect anti-HBs assay on the Architect i2000 system (Abbott) | ||||
CMIA | High sensitivity and specificity Automation | High cost, sophisticated equipment, trained technicians, continuous supply of electricity | Architect i2000 analyzer (Abbott Diagnostics) | [44] |
Rapid point-of-care tests | Simplicity, do not need sophisticated equipaments, minimum training to execute the assay, storage and performance at room temperature, results can be read in up to 10 min | Poor performance in seroconversion panels and among individuals infected by several HBV mutants | Determine™ HBsAg (Abbott Laboratories) | [49-56] |
Virucheck® HBsAg (Orchid Biomedical Systems) | ||||
Cypress HBsAg (Cypress Diagnostics) | ||||
Hexagon® HBsAg (Human) | ||||
Cortez Rapidtest (Cortez Diagnostics) | ||||
VIKIA HBsAg (Biomériuex) | ||||
Quick Profile™ (Lumiquick) | ||||
DRW-HBsAg v2.0 (Diagnostics for the Real WorldTM) | ||||
AMRAD ICT | ||||
Binax | ||||
Advanced quality™ one step test (Intec Products) |
- Citation: Villar LM, Cruz HM, Barbosa JR, Bezerra CS, Portilho MM, Scalioni LP. Update on hepatitis B and C virus diagnosis. World J Virology 2015; 4(4): 323-342
- URL: https://www.wjgnet.com/2220-3249/full/v4/i4/323.htm
- DOI: https://dx.doi.org/10.5501/wjv.v4.i4.323