Copyright
©2013 Baishideng Publishing Group Co.
World J Transplant. Dec 24, 2013; 3(4): 127-133
Published online Dec 24, 2013. doi: 10.5500/wjt.v3.i4.127
Published online Dec 24, 2013. doi: 10.5500/wjt.v3.i4.127
Baseline | Reperfusion | P value | |
Cardiac output (L/min) | 7.32 ± 1.88 | 9.1 ± 2.62 | < 0.0001 |
Ejection fraction (%) | 38.14 ± 7.78 | 39.75 ± 7.76 | 0.183 |
End diastolic volume (mL) | 216.24 ± 55.82 | 242.34 ± 64.54 | < 0.0001 |
Mixed venous oxygen saturation | 83.80 ± 3.99 | 85.17 ± 4.37 | 0.017 |
Heart rate (beat/min) | 89.81 ± 13.49 | 101.41 ± 13.71 | < 0.0001 |
Mean arterial blood pressure | 77.71 ± 9.47 | 71.29 ± 11.64 | < 0.0001 |
Systemic vascular resistance | 793.76 ± 244.67 | 581.92 ± 196.8 | < 0.0001 |
Mean pulmonary artery pressure | 17.52 ± 3.82 | 20.17 ± 4.8 | < 0.0001 |
Pulmonary vascular resistance | 58.07 ± 26.32 | 52.13 ± 24.76 | 0.078 |
Pulmonary capillary wedge pressure | 12.42 ± 3.44 | 14.82 ± 3.8 | < 0.0001 |
Central venous pressure | 9.53 ± 3.63 | 11.42 ± 3.46 | < 0.0001 |
- Citation: Hilmi IA, Planinsic RM, Nicolau-Raducu R, Damian D, Al-Khafaji A, Sakai T, Abu-Elmagd K. Isolated small bowel transplantation outcomes and the impact of immunosuppressants: Experience of a single transplant center. World J Transplant 2013; 3(4): 127-133
- URL: https://www.wjgnet.com/2220-3230/full/v3/i4/127.htm
- DOI: https://dx.doi.org/10.5500/wjt.v3.i4.127