Copyright
©The Author(s) 2024.
World J Transplant. Sep 18, 2024; 14(3): 95233
Published online Sep 18, 2024. doi: 10.5500/wjt.v14.i3.95233
Published online Sep 18, 2024. doi: 10.5500/wjt.v14.i3.95233
Factor | Received kidney 1 (n = 61) | Received kidney 2 (n = 61) | P value |
DCDD (%) | 42 (69) | 42 (69) | 1.0 |
ECD (%) | 19 (31) | 19 (31) | 1.0 |
HMP time (HR, 95%CI) | 5.2 (4.5, 5.8) | 10.8 (9.9, 11.7) | < 0.0001b |
Static cold storage time (HR, 95%CI) | 3.7 (3.1, 4.3) | 3.9 (3.1, 4.7) | 0.38 |
Total CIT (HR, 95%CI) | 8.9 (7.9, 9.8) | 14.7 (13.7, 15.8) | < 0.0001b |
WIT2 (min, 95%CI) | 52 (47, 57) | 53(48, 59) | 0.81 |
- Citation: Verdiales C, Baxter L, Lim HJ, Beck G, Moser MA. Matched pair analysis of the effect of longer hypothermic machine perfusion time on kidney transplant outcomes. World J Transplant 2024; 14(3): 95233
- URL: https://www.wjgnet.com/2220-3230/full/v14/i3/95233.htm
- DOI: https://dx.doi.org/10.5500/wjt.v14.i3.95233