Copyright
©The Author(s) 2024.
World J Transplant. Jun 18, 2024; 14(2): 91081
Published online Jun 18, 2024. doi: 10.5500/wjt.v14.i2.91081
Published online Jun 18, 2024. doi: 10.5500/wjt.v14.i2.91081
Ref. | Sissingh et al[22], 2023 | Warner et al[18], 2020 | Martins et al[27], 2018 | Tal et al[26], 2017 | Cote et al[28], 2016 | Kaffes et al[19], 2014 |
n | 80 | 62 | 59 | 48 | 73 | 20 |
FCSEMS removal protocol, months | 6 | 3 | 6 | 4-6 | 6-12 | 3 |
Median stent indwelling time, months | NA | 10 | 5 | 6 | 6 | 4 |
Stricture resolution (%) | 93 | 96 | 83 | 100 | 89 | 100 |
Stricture recurrence (%) | 33 | 25 | 32 | 21 | 15 | 30 |
Migration rate (%) | 16 | NA | 10 | 21 | 45 | 0 |
Acute pancreatitis (%) | 7 | 5 | 13 | NA | 6 | NA |
Cholangitis rate (%) | 7 | 4 | 2 | NA | 3 | 10 |
Bile duct perforation (%) | 0 | 2 | NA | NA | NA | NA |
- Citation: Lim C, Ng J, Sarraf B, Vaughan R, Efthymiou M, Zorron Cheng Tao Pu L, Chandran S. Safety and efficacy of Kaffes intraductal self-expanding metal stents in the management of post-liver transplant anastomotic strictures. World J Transplant 2024; 14(2): 91081
- URL: https://www.wjgnet.com/2220-3230/full/v14/i2/91081.htm
- DOI: https://dx.doi.org/10.5500/wjt.v14.i2.91081