Copyright
©The Author(s) 2024.
World J Transplant. Jun 18, 2024; 14(2): 91081
Published online Jun 18, 2024. doi: 10.5500/wjt.v14.i2.91081
Published online Jun 18, 2024. doi: 10.5500/wjt.v14.i2.91081
Stricture outcomes | ≤ 120 d | > 120 d | P value |
n | 7 | 21 | |
Median duration of stent course, d (IQR, d) | 95 (90-116) | 183 (167-193) | |
Stricture resolution on Kaffes removal, n (%) | 7 (100.0) | 20 (95.0) | 1.00 |
Recurrence | |||
n (%) | 5 (71.0) | 2 (10.0) | 0.01a |
Median days to recurrence (IQR) | 248 (27-812) | 1139 (785-1493) | 0.19 |
- Citation: Lim C, Ng J, Sarraf B, Vaughan R, Efthymiou M, Zorron Cheng Tao Pu L, Chandran S. Safety and efficacy of Kaffes intraductal self-expanding metal stents in the management of post-liver transplant anastomotic strictures. World J Transplant 2024; 14(2): 91081
- URL: https://www.wjgnet.com/2220-3230/full/v14/i2/91081.htm
- DOI: https://dx.doi.org/10.5500/wjt.v14.i2.91081