Copyright
©The Author(s) 2024.
World J Transplant. Jun 18, 2024; 14(2): 91081
Published online Jun 18, 2024. doi: 10.5500/wjt.v14.i2.91081
Published online Jun 18, 2024. doi: 10.5500/wjt.v14.i2.91081
Stricture outcomes | 3 months | 6 months | P value |
Stricture resolution on stent extraction, n (%) | 30 (96.8) | 30 (93.8) | 0.72 |
Stricture recurrence, n (%) | 14 (42.4) | 3 (9.1) | 0.01a |
Median days to recurrence since stent removal, d (IQR, d) | 273 (73-1192) | 431 (7-617) |
- Citation: Lim C, Ng J, Sarraf B, Vaughan R, Efthymiou M, Zorron Cheng Tao Pu L, Chandran S. Safety and efficacy of Kaffes intraductal self-expanding metal stents in the management of post-liver transplant anastomotic strictures. World J Transplant 2024; 14(2): 91081
- URL: https://www.wjgnet.com/2220-3230/full/v14/i2/91081.htm
- DOI: https://dx.doi.org/10.5500/wjt.v14.i2.91081