Clinical criteria | Objective criteria |
Primary disease for which patient needed IMV is improving; good cough reflex; absence of secretions | Respiratory; SaO2 > 90% with FiO2 < 0.4 (Pf > 150), PEEP < 8 cm H2O; RR < 35/min; MIP < 20-25 cm H2O; Vt > 5 mL/kg on SBT; VC > 10 mL/kg; No acidosis. Cardiovascular; HR < 140/min; SBP 90-160 mmHg with minimal to no vasopressors; neurological; conscious or adequate mental status with good airway reflexes |
- Citation: Gupta A, Singh O, Juneja D. Clinical prediction scores predicting weaning failure from invasive mechanical ventilation: Role and limitations. World J Crit Care Med 2024; 13(4): 96482
- URL: https://www.wjgnet.com/2220-3141/full/v13/i4/96482.htm