Table 1 Mean and standard deviation of correct raw score (words) with different number of channels at various signal-to-noise ratios
-5 dB SNR
0 dB SNR
+5 dB SNR
MeanSDMeanSDMeanSD
4 channels4.003.255.263.278.635.14
8 channels15.105.8418.004.8419.864.04
32 channels23.905.1725.633.7126.931.70