Table 2 Main parameters derived from dynamic contrast enhanced-magnetic resonance imaging studies
ParameterBiological meaning
Area under the curveThe integral in a plot of concentration of contrast agent in blood plasma against time
Maximum (relative) enhancementThe maximum signal difference between the signal intensity at its maximum and baseline
Time to peakTime elapsed between the arterial peak and the end of the steepest portion of enhancement
Wash in rateThe maximum slope between the time of onset of contrast inflow and the time of peak enhancement on the time intensity curve
Wash out rateThe clearance rate of contrast agent
KtransVolume transfer constant between blood plasma and EES
KepRate constant between EES and blood plasma
VeVolume of EES per unit of volume of tissue