Table 2 Digital inclinometer reliability of humeral range of motion measurements
Ref.MotionReliabilityICCSEMMDC
Kolber et al[74]FlexionIntra-day, inter-observer0.583.24°
Inter-day, intra-observer0.831.64°
AbductionIntra-day, inter-observer0.951.63°
Inter-day, intra-observer0.912.26°
Internal rotationIntra-day, inter-observer0.933.39°
Inter-day, intra-observer0.874.27°
External rotationIntra-day, inter-observer0.883.98°
Inter-day, intra-observer0.942.63°
Kolber et al[44]ScaptionIntra-day, inter-observer0.893.4°
Inter-day, intra-observer0.883.4°
Laudner et al[43]Horizontal adductionIntra-observer0.931.64
Inter-observer0.911.71
de Winter[65]AbductionInter-observer0.28–0.83
External rotationInter-observer0.56–0.90