Copyright
©2014 Baishideng Publishing Group Co.
World J Orthop. Apr 18, 2014; 5(2): 112-123
Published online Apr 18, 2014. doi: 10.5312/wjo.v5.i2.112
Published online Apr 18, 2014. doi: 10.5312/wjo.v5.i2.112
Grade | Breach |
1 | None |
2 | Lateral, but screw tip is within VB |
3 | Anterior or lateral breach of screw tip |
4 | Medial or inferior breach |
5 | Breach that requires immediate revision (due to proximity to sensitive structures) |
- Citation: Puvanesarajah V, Liauw JA, Lo SF, Lina IA, Witham TF. Techniques and accuracy of thoracolumbar pedicle screw placement. World J Orthop 2014; 5(2): 112-123
- URL: https://www.wjgnet.com/2218-5836/full/v5/i2/112.htm
- DOI: https://dx.doi.org/10.5312/wjo.v5.i2.112