Copyright
©The Author(s) 2023.
World J Orthop. May 18, 2023; 14(5): 340-347
Published online May 18, 2023. doi: 10.5312/wjo.v14.i5.340
Published online May 18, 2023. doi: 10.5312/wjo.v14.i5.340
Variable | OR | Lower 95% | Upper 95% | Z score | P value |
Bovie | 0.3 | 0.2 | 0.4 | -6.0 | < 0.001 |
Burring | 1.0 | 0.4 | 2.2 | 0.0 | 0.962 |
Drilling | 0.2 | 0.1 | 0.7 | -2.5 | 0.011 |
Bone scalpel | 1.3 | 0.3 | 5.7 | 0.4 | 0.724 |
Max in room | 1.7 | 0.9 | 3.5 | 1.6 | 0.111 |
Sensor distance | 0.02 | 0.001 | 0.2 | -3.0 | 0.003 |
- Citation: Langner JL, Pham NS, Richey A, Oquendo Y, Mehta S, Vorhies JS. Spinal fusion is an aerosol generating procedure. World J Orthop 2023; 14(5): 340-347
- URL: https://www.wjgnet.com/2218-5836/full/v14/i5/340.htm
- DOI: https://dx.doi.org/10.5312/wjo.v14.i5.340