Case | Culture after aspiration (positive cultures/nr of total cultures) | Culture after revision (positive cultures/nr of total cultures) |
2 | Propionibacterium acnes (2/2) | Cutibacterium acnes (8/9) |
Staphylococcus aureus (1/2) | ||
4 | Negative (2/2) | Staphylococcus capitis (5/8) |
Staphyloccus hominis (1/8) | ||
Staphylococcus epidermidis (1/8) | ||
Propionibacterium acnes (1/8) | ||
7 | Negative (2/2) | Propionibacterium acnes (1/2) |
8 | Negative (1/1) | Staphylococcus capitis (1/6) |
9 | Staphylococcus aureus (1/2) | Staphylococcus aureus (2/6) |
10 | Pseudomonas aeruginosa (1/1) | Pseudomonas aeruginosa (9/9) |
Staphylococcus epidermidis (1/9) | ||
13 | Staphylococcus lugdunensis (2/2) | Staphylococcus lugdunensis (7/7) |
- Citation: Kuiper JW, Pander P, Vos SJ. Good accuracy of the alpha-defensin lateral flow test for hip periprosthetic joint infection: A pilot study in a retrospective cohort of 52 patients. World J Orthop 2020; 11(1): 36-46