Table 1 Discrepancies between bladder and rectal doses as assessed by two-dimensional orthogonal films and computed tomography-image based planning
Orthogonal film based vsCT based
Ling et al[19]Bladder1.0 - 4.1x
Rectum1.4 - 2.5x
Schoeppel et al[20]Bladder2.1 - 2.3x
Rectum1.3 – 1.6x
Stuecklschweiger et al[21]Bladder1.0 - 2.2x
Rectum1.1 - 1.6x
Kapp et al[22]Bladder1.0 – 5.4x
Rectum1.1 – 2.7x