Table 1 Signal intensities and other features on conventional and special magnetic resonance imaging sequences
Case No.T1WT2WT2 FLAIRPost-contrastFlow voidsExtension beyond cavernous sinusVessel encasementDWIBlooming on GRE
1HypoHyperHyperIntense enhancementYesModerateYesHypointenseNo
2HypoHyperHyperIntense enhancementNoModerateYesHypointenseNo
3HypoHyperHyperIntense enhancementNoModerateYesHypointenseNo
4HypoHyperHyperIntense enhancementNoExtensiveYesNot doneNo
5HypoHyperHyperIntense enhancementNoExtensiveDisplaced onlyHypointenseNot done
6HypoHyperHyperIntense enhancementNoNilDisplaced onlyNot doneNot done
7HypoHyperHyperIntense enhancementYesMildYesHypointenseNo
8HypoHyperHyperIntense enhancementCentripetal fillingModerateYesHypointense-
9Iso intenseMildly hyperNot doneIntense enhancementNoModerateYesHypointenseNot done
10HypoHyperNot doneIntense enhancementNoMildYesNot doneNot done
11HypoHyperHyperNot availableNoModerateNoNot doneNot done
12HypoHyperHyperIntense enhancementVascular supply from left ICAExtensiveYesHypointenseNo
13HypoHyperHyperIntense enhancementNoMildYesHypointenseNo
14HypoHyperHyperIntense enhancementNoExtensiveYesHypointenseNot done
15HypoHyperHyperIntense enhancementYesExtensiveYesNot doneNot done