Copyright
©The Author(s) 2016.
World J Radiol. Jun 28, 2016; 8(6): 588-593
Published online Jun 28, 2016. doi: 10.4329/wjr.v8.i6.588
Published online Jun 28, 2016. doi: 10.4329/wjr.v8.i6.588
Iodinated contrast/sequences | Iopamidol magnetic field and concentration | Iodixanol magnetic field and concentration | ||||||
1.5T | 3T | 1.5T | 3T | |||||
100% | 50% | 100% | 50% | 100% | 50% | 100% | 50% | |
T1-SE | 4.2 ± 2 | 1.6 ± 0.7 | 15.2 ± 3.5 | 10.4 ± 3.5 | 20.8 ± 4 | 16 ± 4 | 21.2 ± 3.4 | 16 ± 3 |
T2-SE | 49.3 ± 1 | 27 ± 3 | 92.6 ± 0.3 | 72 ± 1 | 23 ± 1.7 | 6.5 ± 3.8 | 77.5 ± 0.9 | 47 ± 3 |
Gradient-echo | 13.6 ± 0.8 | 3.7 ± 0.6 | 34 ± 0.4 | 23.7 ± 1.4 | 6.3 ± 1.5 | 2.4 ± 1.6 | 37.7 ± 1 | 18.3 ± 0.9 |
Fluid-attenuation-inversion-recovery | 14.5 ± 0.3 | 1.8 ± 0.2 | 40.8 ± 0.3 | 29.6 ± 1 | 4.2 ± 0.2 | 4.9 ± 0.5 | 32.3 ± 0.4 | 14.8 ± 1.5 |
Statistics: Kruskall-Wallis test | P < 0.001 | P < 0.001 | P < 0.00 | P < 0.00 | P < 0.001 | P < 0.004 | P < 0.00 | P < 0.002 |
- Citation: Morales H, Lemen L, Samaratunga R, Nguyen P, Tomsick T. Effects of iodinated contrast on various magnetic resonance imaging sequences and field strength: Implications for characterization of hemorrhagic transformation in acute stroke therapy. World J Radiol 2016; 8(6): 588-593
- URL: https://www.wjgnet.com/1949-8470/full/v8/i6/588.htm
- DOI: https://dx.doi.org/10.4329/wjr.v8.i6.588