Copyright
©The Author(s) 2016.
World J Radiol. Nov 28, 2016; 8(11): 857-867
Published online Nov 28, 2016. doi: 10.4329/wjr.v8.i11.857
Published online Nov 28, 2016. doi: 10.4329/wjr.v8.i11.857
Tesla | Respiratory | b-value (× 10-3 s/mm2) | Tumor | Results | |
Kim et al[97] | 3 | RT | 0, 100, 800 | Mets | Combined EOB-MRI and DWI yielded better accuracy and sensitivity |
(Various) | |||||
Chung et al[98] | 3 | FB | 50, 400, 800 | Mets | Combined EOB-MRI and DWI yielded better accuracy and sensitivity |
(colorectal) | |||||
Koh et al[99] | 1.5 | FB | 0, 50, 100, 250, 500, 750 | Mets | Combined EOB-MRI and DWI improved detection |
(colorectal) | |||||
Löwenthal et al[100] | 1.5 | BH | 0, 500 | Mets | DWI can detect small lesions |
(colorectal) | |||||
Shimada et al[101] | 3 | RT | 0, 500 | Mets | EOB-MRI showed higher accuracy |
(Various) | |||||
Donati et al[102] | 1.5 | BH | 0, 150, 500 | Mets | No added value of DWI |
(Various) | |||||
Kim et al[103] | 1.5 | RT | 0, 50, 600 | Mets, HCC | DWI increases sensitivity for detecting Mets |
No added value of DWI for HCC detection |
- Citation: Saito K, Tajima Y, Harada TL. Diffusion-weighted imaging of the liver: Current applications. World J Radiol 2016; 8(11): 857-867
- URL: https://www.wjgnet.com/1949-8470/full/v8/i11/857.htm
- DOI: https://dx.doi.org/10.4329/wjr.v8.i11.857