Ref. | System | Field strength (T) | Sequence | TR/TE (ms/ms) | No. of patients/mean age (SD) (yr) | b-values (s/mm2) | Mean ADC (SD) (× 10-3 mm2/s) |
Müller et al[60], 1994 | Siemens | 1.5 | STEAM EPI, BH | 2BH/18 | 10 (7F, 3M)/24 | 2, 8, 22, 32, 57, 89, 176, 395 | 1.39 (0.16) |
Ichikawa et al[28], 1998 | Siemens Vision | 1.5 | SS SE EPI, BH, FS | NR/54 | 46 (14F, 32M)/58 | 1.6, 16, 55 | 2.28 (1.23) |
Yamada et al[24], 1999 | Siemens Vision | 1.5 | SS SE EPI, BH, FS | NR/123 | 47 | 0, 30, 300, 900, 1100 | 0.87 (0.26) |
Kim et al[29], 1999 | GE Signa | 1.5 | SS SE EPI, BH (6s), FS | NR/70 | P1: 6 (1F, 5M)/29 P2: 48 (18F, 30M)/57 | 3, 57, 192, 408, 517, 705, 846 | b < 850: P1: 1.05 (0.30) P2: 1.02 (0.25) b < 410: P1: 1.55 (0.37) P2: 1.16 (0.42) b < 100: P1: 4.80 (2.37) P2: 3.55 (1.75) |
Moteki et al[25], 2002 | Siemens Impact | 1.0 | Turbo FLASH, BH, FA = 12° | 8.8/4 | 46 | 0, 50.2, 295 | 1.11 (1.02), 12.3 (5.17) |
1Mürtz et al[32], 2002 | Philips Intera | 1.5 | SS EPI, RT, BHE, SPIR + four saturation slabs | (1) RT, 4HB/83 (2) 3000/83 | 12 (4F, 8M)/31 | 50, 300, 700, 1000, 1300 | (1) 0.92-0.96 (0.09-0.14) (2) 1.03-1.14 (0.22-0.40) |
Boulanger et al[155], 2003 | GE Signa | 1.5 | SS EPI, BH | 3000/52 | 10 (2F, 8M)/43.5 | 50, 100, 150, 200, 250 | 1.79 (0.25) |
Chow et al[55], 2003 | GE Signa | 1.5 | SS EPI | 3000/(46.9-57.5) | 12 (4F, 8M)/29 | 10, 300 | 1.697 (0.052) |
Taouli et al[47], 2003 | Philips Intera | 1.5 | SS EPI, BH, FS | (1) 2400/ 104 | 14 | (1) 0, 500 | (1) 1.83 (0.36) |
(2) 3106/ 104 | (2) 0, 134, 267, 400 | (2) 1.51 (0.49) | |||||
Taouli et al[39], 2004 | Philips Intera | 1.5 | SS EPI, FS | (1800-2400)/(63-83) | 10 (3F, 7M)/33 | 0, 500 | NPI: 1.60 (0.13) |
PI: 1.52 (0.15) | |||||||
DTI + PI: 1.51 (0.21) | |||||||
Deng et al[156], 2006 | Siemens Sonata | 1.5 | (1) SS SE EPI, BH | 2000/82 | 9 | 0, 502 | (1) 1.18 (0.14) |
(2) MS PROPELLER, FB, RT, FS + 2 saturation slabs | 2000/105 | (2) 1.39 (0.19) | |||||
Lewin et al[157], 2007 | Siemens Maestro | 1.5 | SS SE EPI, NC, FS | 1400/76 | 20 (9F, 11M)/31.4 (7) | 0, 200, 400, 800 | 1.44 (0.02) |
Taouli et al[158], 2007 | Siemens Avanto | 1.5 | SS EPI, BH, FS | 1300/(51-71) | 7 (2F, 5M)/32 | 0, 50, 300, 500, 700, 1000 | 1.66 (0.12) |
Luciani et al[159], 2008 | Siemens Avanto | 1.5 | RT | 1500/70 | 25 (13F, 12M)/48 (16) | 0, 200, 400, 800 | 1.39 (0.2) |
Bruegel et al[160], 2008 | Siemens Avanto | 1.5 | SS EPI, NC, BH, FS | NR/69 | 102 (46F, 56M)/61 | 50, 300, 600 | 1.24 (0.15) |
Braithwaite et al[49], 2009 | Siemens Trio | 3.0 | Stimulated echo EPI, FB, FS | 3200/76 | 20 (20M)/34.7 | 0, 400 | 2.4 (0.50) E |
2Saremi et al[161], 2011 | a. Siemens Avanto | a. 1.5 | SS SE EPI, FS | (1) 150/75 | 13 (2F, 11M)/46 (13) | 50, 400, 1000 | a. 0.86(0.2) |
b. Siemens Trio | b. 3.0 | (1) BH, no PI | (2) 144/72 | b. 0.83(0.2) | |||
(2) BH, PI | (3) 174/87 | ||||||
(3) FB, PI | |||||||
Watanabe et al[51], 2011 | Philips Achieva | 3.0 | SS EPI, BH | 2291/44 | 18 | 0, 500 | 1.36 (0.11) |
Bakan et al[162], 2012 | Siemens Avanto | 1.5 | SS SE EPI, FS | 4800/82 | 25 (11F, 14M)/39.8 (11.4) | 0, 500, 1000 | 1.75 (0.14) |
Miquel et al[34], 2012 | Philips Achieva | 1.5 | SS SE EPI, FB | (5300-5800)/62 | 10 (7F, 3M)/32.3 (4.6) | 100, 200, 500, 750, 1000 | V1: 1.05 (0.04) V2: 1.06 (0.07) |
3Andreou et al[163], 2013 | Siemens Avanto | 1.5 | SS SE EPI, NC, RT, FS | 5000/68 | 14 (7F, 7M)/59.7 | 0, 25, 50, 75, 100, 250, 500, 900 | 1.22 |
Corona-Villalobos et al[58], 2013 | Siemens Avanto | 1.5 | SS SE EPI, BH | (1) 3000/(69-79) | 100 (36F, 64M)/60.4 (14.3) | (1) 0, 750 | (1) 1.22 (0.15) |
(2) 2500/(76-95) | (2) 0, 50, 100, 200, 300, 450, 600, 750 | (2) 0.96 (0.08) | |||||
Klasen et al[63], 2013 | Siemens Avanto | 1.5 | SS EPI | (6825-6930)/(68-76) | 50 (30F, 20M)/55.1 | 50, 300, 600 | O1: 1.053 (0.124) |
O2: 1.088 (0.146) | |||||||
Larsen et al[48], 2013 | Philips Achieva | 3.0 | SS SE EPI, BHI, BHE, RT, FB, FS | (1600-2000)/71-72 | 10 (4F, 6M)/24 | 0, 150, 500, 750, 1000 | b = 0, 750: |
BHI: 1.52 (0.11) | |||||||
BHE: 1.54 (0.1) | |||||||
FB: 1.44 (0.11) | |||||||
RT: 1.48 (0.11) | |||||||
b = 150, 750: | |||||||
BHI: 0.81 (0.09) | |||||||
BHE: 0.83 (0.10) | |||||||
FB: 0.91 (0.08) | |||||||
RT: 0.92 (0.07) | |||||||
Penner et al[164], 2013 | Philips Intera | 1.5 | SS SE EPI, RT, SPIR | 1648/63 | 15 (12F, 3M)/44 (11) | 0, 50, 800 | 1.30 (0.11) |
Donati et al[56], 2014 | (1) Siemens Sonata | 1.5 | SS SE EPI, FB, FS | (5000-6225)/(36-76) | 10 (10M)/36.6 (7.7) | 0, 1000 | (1) LL: 1.207 (0.194) |
(2) Siemens Trio | 3.0 | RL: 1.026 (0.260) | |||||
(3) Philips Achieva | 1.5 | (2) LL: 1.132 (0.250) | |||||
(4) Philips Achieva | 3.0 | RL: 0.966 (0.187) | |||||
(5) GE Signa | 1.5 | (3) LL: 1.349 (0.178) | |||||
(6) GE Discovery | 3.0 | RL: 1.128 (0.127) | |||||
(4) LL: 1.097 (0.129) | |||||||
RL: 1.108 (0.110) | |||||||
(5) LL: 1.271 (0.133) | |||||||
RL: 1.151 (0.162) | |||||||
(6) LL: 1.524 (0.356) | |||||||
RL: 1.280 (0.372) | |||||||
Leporq et al[33], 2015 | GE Discovery | 3.0 | SE EPI, RT, FB, No FS | 2000/(48-55) | 25 (9F, 16M)/27.1 (4.5) | 0, 800 | RT: 1.65 (0.28) |
FB + (TE = 48): 1.63 (0.22) | |||||||
FB + (TE = 55): 1.57 (0.26) | |||||||
FB + WA: | |||||||
1.55 (0.24) | |||||||
Duran et al[165], 2015 | Philips Intera | 1.5 | SS EPI, FB, SPIR | 3448/63 | 53 (33F, 20M)/50 | 0, 150, 600 | 1.52 (0.32) |