C-arm computed tomography | Multidetector computed tomography | P value | |
Mean long axis (mm) | 28.1 ± 8.1 | 27.3 ± 8.1 | 0.134 |
Mean short axis (mm) | 19.9 ± 4.8 | 19.3 ± 5.1 | 0.161 |
Mean estimated ablative area (mm2) | 462.5 ± 202.1 | 441.2 ± 212.5 | 0.206 |
Mean ablative margin (mm) | 6.4 ± 2.2 | 6.0 ± 2.4 | 0.159 |
Insufficient safety margin detection (%) | 39.6 (19/48) | 41.6 (20/48) | 0.569 |
- Citation: Iwazawa J, Ohue S, Hashimoto N, Mitani T. Ablation margin assessment of liver tumors with intravenous contrast-enhanced C-arm computed tomography. World J Radiol 2012; 4(3): 109-114