Author | Yr | CT scanner | Acquisition phase | kVp | mA(mAs) | Pitch | CTDIvol in mGy | DLP in mGy cm | Supplements |
Kim et al[49] | 2003 | 4MDCT | Unenhanced | 120 | 200 | 1.5 | 10.19 | NA | |
Renal CTA | 12.88 | NA | |||||||
Excretory | 10.19 | NA | |||||||
Wintersperger et al[50] | 2005 | 16MDCT | Abdominal CTA | 120 | 400 (200) | 1 | 15.6 | 673.9 | |
100 | 10.0 | 447.0 | |||||||
Sahani et al[45] | 2007 | 16MDCT | Renal CTA | 140 | (210) | 0.94 | 25 ± 3 | NA | AEC |
120 | 17 ± 4 | NA | Using NI of 15 | ||||||
100 | 12 ± 3 | NA | |||||||
Zamboni et al[42] | 2010 | 64MDCT | Low dose 4-phase | 120 | 50-150 | NA | NA | 2021 ± 545 | |
Low dose 3-phase | NA | 1501 ± 418 | AEC | ||||||
Low dose 2-phase | NA | 981 ± 381 | Using NI of 15.86 | ||||||
Low dose 2-phase* | NA | 676 ± 284 |
- Citation: Sung MK, Singh S, Kalra MK. Current status of low dose multi-detector CT in the urinary tract. World J Radiol 2011; 3(11): 256-265
- URL: https://www.wjgnet.com/1949-8470/full/v3/i11/256.htm
- DOI: https://dx.doi.org/10.4329/wjr.v3.i11.256