Review
Copyright ©2011 Baishideng Publishing Group Co.
World J Radiol. Nov 28, 2011; 3(11): 256-265
Published online Nov 28, 2011. doi: 10.4329/wjr.v3.i11.256
Table 4 Radiation dose and computed tomography scanning parameters of computed tomography urography using standard dose and low dose protocols
AuthorsYrCT scannerAcquisiton phasekVpmA (mAs)PitchEffective dose (mSv)Supplement
Standard CT urographic protocols
Caoili et al[26]20024MDCTUnenhanced120150-2400.7525-35
Nephrographic100-2800.75
Excretory150-2801.5
Nawfel et al[25]20044MDCTUnenhanced120(155-200)1.0-1.256.4 ± 1.3
Nephrographic(155-200)1.0-1.252.5 ± 0.34
Excretory(165-185)0.65-1.05.9 ± 1.5
Low dose CT urographic protocols
Coppenrath et al[27]20064MDCTExcretory90(15-100)0.875-1.750.78 (male)/1.08 (female)
16MDCT100(17-100)1-1.51.06-1.19 (male)
0.76-0.86 (female)
Kemper et al[28]20074MDCTExcretory120(70)1.252.7 (male)/4.1(female)
Yanaga et al[29]200940MDCTExcretory80(300)0.7812.9Adaptive noise reduction filter
Kekelidze et al[30]201016MDCTUnenhanced120(55)0.753.4AEC
Enhanced(165)1.259.8Split-bolus technique