Table 4 Comparison of negative and positive lymph nodes by their long axis and short axis diameters and derived values (product and ratio of long axis and short axis), presence of fatty hilum, and signal intensity on diffusion weighted images with background suppression
Negative LN regions (n = 127) median (IQR) | Positive LN regions (n = 27) median (IQR) | P value | AUC (95%CI) | P value | |
Long axis (mm) | 17 (12-21) | 28 (22-36) | < 0.0001 | 0.87 (0.80 to 0.95) | < 0.0001 |
Short axis (mm) | 7 (6-8) | 14 (10-25) | < 0.0001 | 0.87 (0.79 to 0.96) | < 0.0001 |
LA × SA (mm × mm) | 120 (72-161) | 420 (210-936) | < 0.0001 | 0.89 (0.81 to 0.97) | < 0.0001 |
LA: SA | 2.3 (1.8-2.8) | 1.8 (1.5-2.3) | 0.0039 | 0.68 (0.56 to 0.81) | 0.0032 |
Fatty hilum (0-3)1 | 1 (0.0-2.3) | 0 (0-1) | 0.0015 | 0.69 (0.58 to 0.79) | 0.0023 |
DWIBS (0-3) | 2 (2-3) | 3 (3-3) | < 0.0001 | 0.71 (0.62 to 0.80) | 0.00059 |
- Citation: Lambert L, Wagnerova M, Vodicka P, Benesova K, Zogala D, Trneny M, Burgetova A. Whole-body magnetic resonance imaging provides accurate staging of diffuse large B-cell lymphoma, but is less preferred by patients. World J Radiol 2025; 17(1): 99207
- URL: https://www.wjgnet.com/1949-8470/full/v17/i1/99207.htm
- DOI: https://dx.doi.org/10.4329/wjr.v17.i1.99207