Pre training | ORADS 1, % | ORADS 2, % | ORADS 3, % | ORADS 4, % | ORADS 5, % |
Sensitivity | |||||
R1 | 90 (55.5 to 99.8) | 100 (69.5 to 100) | 100 (59.0 to 100) | 92 (61.5 to 99.8) | 55 (23.4 to 83.3) |
R2 | 90% (55.5 to 99.8) | 100% (69.2 to 100) | 71 (29.0 to 96.3) | 92 (61.5 to 99.8) | 82 (48.2 to 97.7) |
R3 | 90 (55.5 to 99.8) | 100 (69.2 to 100) | 100 (59.0 to 100) | 75 (42.8 to 94.5) | 55 (23.4 to 83.3) |
Specificity | |||||
R1 | 100 (91.2 to 100) | 85 (70.2 to 94.3) | 98 (87.7 to 99.4) | 100 (90.8 to 100) | 100 (91.0 to 100) |
R2 | 100 (91.2 to 100) | 90 (76.3 to 97.2) | 98 (87.7 to 99.4) | 97 (86.2 to 99.9) | 100 (91.0 to 100) |
R3 | 98 (86.8 to 99.9) | 90 (76.3 to 97.2) | 95 (84.2 to 99.4) | 95 (82.3 to 99.4) | 100 (91.0 to 100) |
PPV | |||||
R1 | 100 | 63 (44.4 to 77.7) | 88 (50.2 to 98.0) | 100 | 100 |
R2 | 100 | 71 (49.7 to 86.4) | 83 (40.5 to 97.4) | 92 (61.2 to 98.7) | 100 |
R3 | 90 (56.2 to 98.4) | 71 (49.7 to 86.4) | 78 (47.5 to 93.1) | 82 (52.9 to 94.8) | 100 |
NPV | |||||
R1 | 98 (86.2 to 99.6) | 100 | 100 | 97 (85.3 to 99.6) | 89 (80.3 to 93.7) |
R2 | 98 (86.2 to 99.6) | 100 | 96 (86.7 to 98.6) | 97 (85.0 to 99.6) | 95 (84.8 to 98.6) |
R3 | 98 (85.9 to 99.6) | 100 | 100 | 93 (81.8 to 97.0) | 89 (80.3 to 93.7) |
- Citation: Katlariwala P, Wilson MP, Pi Y, Chahal BS, Croutze R, Patel D, Patel V, Low G. Reliability of ultrasound ovarian-adnexal reporting and data system amongst less experienced readers before and after training. World J Radiol 2022; 14(9): 319-328