Characteristics | Carbon dioxide | Iodinated contrast agents |
Overall sensitivity | Less | Higher |
Overall specificity | Less | Higher |
Nephrotoxicity | No | Yes |
Allergenic | No | Yes |
Cost | Low | High |
Ease of administration | Cumbersome | Easier |
Limitations | Visibility and air contamination | Dose related toxicity and allergy |
Delivery via small caliber catheters | Possible | Difficult |
Radiation exposure | Increased if digital subtraction angiography used | Standard |
Dose | Rate related toxicity | Volume related nephrotoxicity |
Contraindications | Pulmonary-systemic communications; not for use in heart, brain or spinal vasculature | Allergy, nephrotoxicity |
Hepatotoxicity | Rare | Rare |
Quality of image | Good | Better |
Procedure duration | Increased | Standard |