Copyright
©The Author(s) 2015.
World J Cardiol. Aug 26, 2015; 7(8): 442-448
Published online Aug 26, 2015. doi: 10.4330/wjc.v7.i8.442
Published online Aug 26, 2015. doi: 10.4330/wjc.v7.i8.442
1st cohort | 2nd cohort | 3rd cohort | 4th cohort | |
No. of patients | 30 | 30 | 30 | 30 |
Procedure technique | Double TSP-C Circular mapping catheter Imaging integration (CT scan) | Unchanged | Unchanged | Unchanged |
NF technology | 2nd generation NF 3-DS (CARTO XP) | 3rd generation NF 3-DS (CARTO3) | Unchanged | CARTO3 + contact force sensing |
Technology feature for NF use | NF visualization of the mapping/ablation catheter | NF visualization of all inserted catheter | Unchanged | Monitoring of the electrode/tissue contact added |
NF 3-DS optimization | Yes | No | Yes (Table 2) | Yes (Table 2) |
Timing | Last 30 cases with CARTO XP | First 30 cases with CARTO3 | After 12 mo | After 12 mo |
- Citation: Ponti RD. Reduction of radiation exposure in catheter ablation of atrial fibrillation: Lesson learned. World J Cardiol 2015; 7(8): 442-448
- URL: https://www.wjgnet.com/1949-8462/full/v7/i8/442.htm
- DOI: https://dx.doi.org/10.4330/wjc.v7.i8.442