Case Control Study
Copyright ©The Author(s) 2023.
World J Cardiol. Nov 26, 2023; 15(11): 582-598
Published online Nov 26, 2023. doi: 10.4330/wjc.v15.i11.582
Table 6 Odds ratios for permanent pacemakers implantation

OR
95%CI
P value
Age (per 5 yr)0.950.8-1.120.549
Male1.000.57-1.760.996
Prior AV replacement0.210.03-1.550.125
CAD1.310.53-3.250.563
HF1.290.37-4.480.693
Self-expanding (Reference: balloon)1.250.71-2.200.442
Prior conduction defect-RBBB3.731.92-7.26< 0.001
Prior conduction defect-LBBB1.110.40-3.030.845
Prior conduction defect-LFAB1.810.56-5.830.319
Valve index1.000.98-1.020.806
Abnormal QRS (≥ 120 ms)3.451.91-6.23< 0.001
Prolonged QTc (≥ 470 ms)2.941.64-5.28< 0.001
Aortic valve area > 0.751.310.73-2.360.364
High preoperative risk (Reference: Low)2.400.70-8.170.163
Intermediate preoperative risk (Reference: Low)1.890.50-7.140.348
Supraventricular Arrhythmia on pre-op EKG (Reference: Sinus)1.881.03-3.430.039