Protective measures | Evidence1 | Reduction | Operator protection | Patient protection |
Technical issues | A[2,3,13,14] | 60% | Yes | Yes |
Traditional LPPE | B[5-9,51] | 35-95% | Yes | No |
Surgical caps | D[44] | 3.3% | Yes | No |
Gloves | D[9] | 20-50% | Yes | No |
Radiation-blocking cream | D[46] | 85% | Yes | No |
Shield, curtain and TRPB | B[9,10-12] | 30-70% | Yes | No |
CathPax® | C[16,20-22] | 70- 80% | Yes | No |
Zero gravity® | C[19] | 78-93% | Yes | No |
RadPad® | A[26,29,30] | 30-35% | Yes | No |
Robotic systems | B[32,34,35,42] | 96% | Yes | No |
- Citation: Gutierrez-Barrios A, Cañadas-Pruaño D, Noval-Morillas I, Gheorghe L, Zayas-Rueda R, Calle-Perez G. Radiation protection for the interventional cardiologist: Practical approach and innovations. World J Cardiol 2022; 14(1): 1-12