Clinical Trials Study
Copyright ©The Author(s) 2018.
World J Cardiol. Nov 26, 2018; 10(11): 222-233
Published online Nov 26, 2018. doi: 10.4330/wjc.v10.i11.222
Table 3 Frequency-domain optical coherence tomography findings in the percutaneous coronary intervention and optimal medical therapy groups
VariableOCT-guided PCI (n = 38)OCT-guided OMT (n = 26)P-value
Reference area mm29.00 (7.56-11.21)9.32 (7.73-12.14)0.507
Minimum luminal area mm22.44 (1.93-3.15)3.43 (2.61-4.72)0.001
Area stenosis %72.22 ± 7.3961.87 ± 7.51< 0.001