Copyright
©The Author(s) 2023.
World J Biol Chem. May 27, 2023; 14(3): 62-71
Published online May 27, 2023. doi: 10.4331/wjbc.v14.i3.62
Published online May 27, 2023. doi: 10.4331/wjbc.v14.i3.62
Table 1 Specific distribution of irregular antibodies in 18 blood donors
Antibody specificity | Number of cases | Percentage of irregular antibodies (%) | IgG classification | Potency |
Anti-D | 7 | 38.91 | IgG | 2-64 |
Anti-E | 2 | 11.11 | IgG | 16-32 |
Anti-cE | 1 | 5.56 | IgG | 8 |
Anti-C | 1 | 5.56 | IgG | 16 |
Anti-PI | 4 | 22.22 | IgM or IgG + IgM | 8-16 |
Anti-M | 1 | 5.56 | IgG | 4-32 |
Anti-N | 1 | 5.56 | IgG | 8.32 |
Anti-Lea | 1 | 5.56 | IgG | 4-16 |
- Citation: He XH, Yan H, Wang CY, Duan XY, Qiao JJ, Guo XJ, Zhao HB, Ren D, Li JS, Zhang Q. Comparison of the conventional tube and erythrocyte-magnetized technology in titration of red blood cell alloantibodies. World J Biol Chem 2023; 14(3): 62-71
- URL: https://www.wjgnet.com/1949-8454/full/v14/i3/62.htm
- DOI: https://dx.doi.org/10.4331/wjbc.v14.i3.62