Retrospective Study
Copyright ©The Author(s) 2024.
World J Gastrointest Surg. Jul 27, 2024; 16(7): 2031-2039
Published online Jul 27, 2024. doi: 10.4240/wjgs.v16.i7.2031
Table 3 Comparison of diffusion coefficient, false diffusion coefficient, and perfusion fraction values of the pancreatic head, body, and tail measured using machines A, B, and C
Region and parameter
Machine A
Machine B
Machine C
Mixed liner model
Post-hoc test
95% limits of agreement
F
P value
Pair comparison
P1 value
PaH
D1.08 ± 0.271.15 ± 0.221.22 ± 0.232.893 0.078 A vs B0.986 -0.56, 0.38
A vs C0.140 -0.47, 0.44
B vs C0.311 -0.32, 0.27
D*0.07 ± 0.040.05 ± 0.030.05 ± 0.022.275 0.128 A vs B0.139 -0.13, 0.03
A vs C0.327 -0.11, 0.03
B vs C0.531 -0.05, 0.04
f0.40 ± 0.180.33 ± 0.150.23 ± 0.0715.725 0.001A vs B0.483 -0.57, 0.16
A vs C0.001 -0.52, 0.00
B vs C0.030 -0.40, 0.06
PaB
D1.05 ± 0.241.09 ± 0.181.21 ± 0.2010.060 0.001 A vs B0.999-0.46, 0.27
A vs C0.003 -0.21, 0.33
B vs C0.027 -0.27, 0.31
D*0.06 ± 0.040.05 ± 0.040.06 ± 0.020.228 0.798 A vs B0.999-0.12, 0.05
A vs C0.999-0.08, 0.04
B vs C0.999-0.09, 0.05
f0.30 ± 0.150.37 ± 0.200.24 ± 0.073.174 0.062 A vs B0.513 -0.36, 0.27
A vs C0.420 -0.39, 0.11
B vs C0.066 -0.57, 0.10
PaT
D1.07 ± 0.161.12 ± 0.221.15 ± 0.182.438 0.112 A vs B0.999-0.42, 0.28
A vs C0.258 -0.34, 0.29
B vs C0.601 -0.19, 0.14
D*0.08 ± 0.040.05 ± 0.030.07 ± 0.029.451 0.001 A vs B0.002 -0.10, 0.00
A vs C0.999-0.11, 0.04
B vs C0.058 -0.06, 0.06
f0.25 ± 0.080.26 ± 0.100.25 ± 0.120.191 0.827 A vs B0.999-0.20, 0.12
A vs C0.999-0.25, 0.13
B vs C0.999-0.27, 0.12