Table 2 An overview of systems used in different studies, the chosen technique of indocyanine green administration and dosage
Ref. | NIR-ICG fluorescence device | ICG dose/concentration | Technique of administration |
Liu et al[12], 2018 | A specific light source (D-Light P, Karl Storz, GmbH & Co. KG, Tuttlingen, Germany) with a NIR-enabled Hopkins 10-mm, 30° laparoscope (Karl Storz, GmbH & Co. KG, Tuttlingen, Germany); a coupled IMAGE1 S camera head; the IMAGE1 S software enhancement mode | 0.125 mg/mL; 10 mL | n = 18 PTGBD; n = 28 percutaneous punctures of the gallbladder with a Veress needle, using 2-0 Prolene stitch |
Graves et al[19], 2017 | A 30-degree 5 mm laparoscope with NIR imaging capability (Stryker Corporation, Kalamazoo, MI, United States) | 0.025 mg/mL ICG-bile solution; 10 mL | Gallbladder puncture with a needle-tipped Kumar cholangiogram catheter or an 8Fr pigtail drainage catheter (Cook, Inc., Bloomington, IN, United States) |
Quaresima et al[20], 2020 | -Karl Storz Image 1S D-Light system (Karl Storz Endoscope GmbH & C. K., Tuttlingen Germany) with a 30° forward oblique vision laparoscope; use of adjunctive filters (Spectra A) intraoperatively | 0.5 mg/mL; 4.0 mL | Gallbladder puncture with a Veress needle and close of the puncture site with suture material |
Jao et al[16], 2020 | Image 1 High-Definition fluorescence laparoscope (Karl Storz Endoscopes, Germany) | 2.5-mg/mL; 5 mL | Via PTGBD |
Gené Škrabec et al[18], 2020 | Olympus EndoEye 3D camera | 0.25 mg/mL; 2-3 mL | Gallbladder puncture with a Veress needle and closure of the entry point with a grasper, a stitch, or a clip |
Cárdenas et al[17], 2021 | Pinpoint fluorescence endoscopic imaging system (Novadaq/Stryker) | 2.5 mg/mL; 2-4 mL | Percutaneous gallbladder puncture under direct vision in the fundus using a 22-gauge epidural needle (Spinocan, Braun); puncture site was closed using forceps |
Shibata et al[21], 2021 | Non stated | 0.025 mg/mL; 1 mL | n = 3 percutaneous gallbladder punctures; n = 8 PTGBD; n = 1 ENBD |
Castagneto-Gissey et al[22], 2022 | Pinpoint Fluorescence Endoscopic Imaging System (Novadaq/Stryker, Burnaby, Canada) | 0.5 mg/mL; 5 mL | Percutaneous gallbladder puncture with a 27-gauge needle |
- Citation: Symeonidis S, Mantzoros I, Anestiadou E, Ioannidis O, Christidis P, Bitsianis S, Bisbinas V, Zapsalis K, Karastergiou T, Athanasiou D, Apostolidis S, Angelopoulos S. Near-infrared cholangiography with intragallbladder indocyanine green injection in minimally invasive cholecystectomy. World J Gastrointest Surg 2024; 16(4): 1017-1029