Variable | B | Standard deviation | Wald | Exp(B) | Odds ratio (95%CI) | P value | |
Lower limit | Upper limit | ||||||
IMBT | |||||||
BMI ≥ 25 kg/m2 | 2.123 | 0.810 | 6.862 | 8.357 | 1.707 | 40.922 | 0.009 |
Neoadjuvant chemotherapy | 1.326 | 0.805 | 2.715 | 3.767 | 0.778 | 18.245 | 0.099 |
Operation time ≥ 4 h | 4.023 | 1.319 | 9.303 | 55.881 | 4.212 | 741.381 | 0.002 |
Inexperienced surgeons | 2.727 | 1.052 | 6.719 | 15.286 | 1.944 | 120.167 | 0.010 |
PAL | |||||||
BMI > 25 kg/m2 | 1.289 | 0.858 | 2.259 | 3.630 | 0.676 | 19.498 | 0.133 |
Preoperative complications | 2.575 | 1.081 | 5.671 | 13.128 | 1.577 | 109.268 | 0.017 |
Neoadjuvant chemotherapy | 1.967 | 0.740 | 7.063 | 7.150 | 1.676 | 30.506 | 0.008 |
TLTG | 2.206 | 1.091 | 4.083 | 9.075 | 1.069 | 77.070 | 0.043 |
- Citation: Deng C, Liu Y, Zhang ZY, Qi HD, Guo Z, Zhao X, Li XJ. How to examine anastomotic integrity intraoperatively in totally laparoscopic radical gastrectomy? Methylene blue testing prevents technical defect-related anastomotic leaks . World J Gastrointest Surg 2022; 14(4): 315-328
- URL: https://www.wjgnet.com/1948-9366/full/v14/i4/315.htm
- DOI: https://dx.doi.org/10.4240/wjgs.v14.i4.315