Copyright
©The Author(s) 2022.
World J Gastrointest Surg. Jan 27, 2022; 14(1): 36-45
Published online Jan 27, 2022. doi: 10.4240/wjgs.v14.i1.36
Published online Jan 27, 2022. doi: 10.4240/wjgs.v14.i1.36
Variable | Group A (n = 37) | Group B (n = 58) | P value |
Surgical procedure, n (%) | |||
Extended left hepatectomy1 | 4 (10.81) | 7 (12.07) | 1.000 |
Extended right hepatectomy2 | 2 (5.41) | 5 (8.62) | 0.855 |
Left hepatectomy | 8 (21.62) | 12 (20.69) | 0.913 |
Right hepatectomy | 5 (13.51) | 8 (13.79) | 0.969 |
Sectionectomy | 8 (21.62) | 9 (15.52) | 0.449 |
Segmentectomy | 7 (18.92) | 8 (13.79) | 0.505 |
Partial resection | 3 (8.11) | 9 (15.52) | 0.457 |
Operative time (min) | 202.86 ± 46.02 | 229.52 ± 57.13 | 0.003 |
Volume of bleeding (mL) | 329.29 ± 97.31 | 398.23 ± 159.61 | 0.010 |
Pringle maneuver (yes/no), n (%) | 14/23 | 31/27 | 0.148 |
Obstructive time of portal vein (min) | 17.71 ± 4.16 | 21.58 ± 5.24 | 0.019 |
- Citation: Zhu LY, Hou JC, Yang L, Liu ZR, Tong W, Bai Y, Zhang YM. Application value of mixed reality in hepatectomy for hepatocellular carcinoma. World J Gastrointest Surg 2022; 14(1): 36-45
- URL: https://www.wjgnet.com/1948-9366/full/v14/i1/36.htm
- DOI: https://dx.doi.org/10.4240/wjgs.v14.i1.36