Copyright
©The Author(s) 2024.
World J Gastrointest Oncol. Jun 15, 2024; 16(6): 2439-2448
Published online Jun 15, 2024. doi: 10.4251/wjgo.v16.i6.2439
Published online Jun 15, 2024. doi: 10.4251/wjgo.v16.i6.2439
Sensitivity | Specificity | PPV | NPV | Accuracy | Youden | |
LI-RADS v2018 | 87.0 | 90.1 | 93.0 | 81.9 | 88.2 | 0.770 |
sLI-RADS A | 81.9 | 90.1 | 92.6 | 76.5 | 85.1 | 0.719 |
sLI-RADS B | 88.4 | 87.2 | 91.3 | 83.1 | 87.9 | 0.756 |
sLI-RADS C | 64.2 | 93.6 | 93.9 | 63.2 | 75.8 | 0.578 |
sLI-RADS D | 89.8 | 89.4 | 92.8 | 85.1 | 89.6 | 0.791 |
F-sLI-RADS | 93.0 | 86.5 | 91.3 | 89.1 | 90.4 | 0.795 |
aPvalue | 0.001 | > 0.999 | — | — | 0.001 | — |
bPvalue | 0.250 | 0.125 | — | — | > 0.999 | — |
cPvalue | < 0.001 | 0.031 | — | — | < 0.001 | — |
dPvalue | 0.031 | > 0.999 | — | — | 0.062 | — |
ePvalue | < 0.001 | 0.062 | — | — | 0.008 | — |
fPvalue | 0.016 | 0.125 | — | — | 0.250 | — |
- Citation: Lyu R, Hu WJ, Wang D, Wang J, Ye YB, Jia KF. Simplified liver imaging reporting and data system for the diagnosis of hepatocellular carcinoma on gadoxetic acid-enhanced magnetic resonance imaging. World J Gastrointest Oncol 2024; 16(6): 2439-2448
- URL: https://www.wjgnet.com/1948-5204/full/v16/i6/2439.htm
- DOI: https://dx.doi.org/10.4251/wjgo.v16.i6.2439