Copyright
©The Author(s) 2023.
World J Gastrointest Oncol. Apr 15, 2023; 15(4): 632-643
Published online Apr 15, 2023. doi: 10.4251/wjgo.v15.i4.632
Published online Apr 15, 2023. doi: 10.4251/wjgo.v15.i4.632
Ref. | Patients, N | Cancer stage | Blood source | PoV sample | CTC isolation method | Detection rate, % (n/N) | Number of CTCs (mean ± SD) | Main findings |
Catenacci et al[22], 2015 | 18 | All | PoV, PV | EUS-guided | CellSearch | PoV: 100 (18/18), PV: 22.2 (4/18) | PoV: 118.4 ± 36.8/7.5 mL, PV: 0.8 ± 0.4/7.5 mL | Both the detection rate and number of CTCs were higher in the PoV than in the PV |
Tien et al[29], 2016 | 41 | Resectable | PoV, PV | Intraoperative | CMx platform | PoV: 58.5 (24/41), PV: 39.0 (16/41) | PoV: 313.4/3 mL, PV: 92.9/3 mL | Both the detection rate and number of CTCs were higher in the PoV than in the PV |
Liu et al[23], 2018 | 29 | Locally advanced, metastatic | PoV, PV | Transabdominal US-guided | ClearCell FX system | PoV: 100 (29/29), PV: 54 (8/14) | PoV: 282.0/7.5 mL, PV: 21.0/7.5 mL | Both the detection rate and number of CTCs were higher in the PoV than in the PV |
Chapman et al[30], 2020 | 171 | All | PoV, PV | EUS-guided | CellSearch | PoV: 100 (17/17), PV: 23.5 (4/17) | PoV: 118.4 (1-516)/7.5 mL2, PV: 0.67 (0-7)/7.5 mL2 | Both the detection rate and number of CTCs were higher in the PoV than in the PV |
Song et al[37], 2020 | 32 | Resectable | PoV, PV | Intraoperative | Microfabricated Filter | PoV: 62.5 (20/32), PV: 68.8 (22/32) | Not shown | No differences in detection rate and number of CTCs between the PoV and PV |
Padillo-Ruiz et al[38], 2021 | 35 | Resectable | PoV, CV | Intraoperative | IsoFluxTM | PoV: 100 (35/35), CV: 100 (35/35) | PoV: 310 (132.1-446.0)/mL3, CV: 405.7 (130.7-533.8)/mL3 | No differences in detection rate and number of CTCs between the PoV and CV |
White et al[40], 2021 | 34 | Resectable | PoV, PV | Intraoperative | CellSearch | PoV: 71 (22/31), PV: 50 (11/22) | Not shown | No differences in detection rate and number of CTCs between the PoV and PV |
Zhang et al[31], 2021 | 31 | All | PoV, PV | EUS-guided | Cyttel detection kit | PoV: 97 (31/30), PV: 87 (27/31) | PoV: 10/5 mL4, PV: 6/5 mL4 | Number of CTCs was higher in the PoV than in the PV |
Choi et al[32], 2022 | 33 | All | PoV, PV | Intraoperative | SMART | PoV: 75.8 (25/33), PB: 92.1 (23/28) | PoV: 2.5/7.5 mL4, PV: 1/7.5 mL4 | Number of CTCs was higher in the PoV than in the PV |
- Citation: Ko SW, Yoon SB. Clinical implications and perspectives of portal venous circulating tumor cells in pancreatic cancer. World J Gastrointest Oncol 2023; 15(4): 632-643
- URL: https://www.wjgnet.com/1948-5204/full/v15/i4/632.htm
- DOI: https://dx.doi.org/10.4251/wjgo.v15.i4.632