Table 2 Clinical outcomes
Endpoint | Value |
Technical success, n (%) | 18 (100) |
Clinical success, n (%) | 18 (100) |
Periprocedural complications, n (%) | 1 (5.5) |
Stent-related complications, n (%) | 5 (27.7) |
Stent occlusion, n (%) | 1 (5.5) |
Stent migration, n (%) | 1 (5.5) |
Mean procedural duration min | 81.5 ± 32.2 |
Median stent patency days (range) | 169 (93-315) |
Overall mortality, n (%) | 4 (22.2) |
- Citation: Cortese F, Acquafredda F, Mardighian A, Zurlo MT, Ferraro V, Memeo R, Spiliopoulos S, Inchingolo R. Percutaneous insertion of a novel dedicated metal stent to treat malignant hilar biliary obstruction. World J Gastrointest Oncol 2022; 14(9): 1833-1843