Copyright
©The Author(s) 2022.
World J Gastrointest Oncol. Aug 15, 2022; 14(8): 1499-1509
Published online Aug 15, 2022. doi: 10.4251/wjgo.v14.i8.1499
Published online Aug 15, 2022. doi: 10.4251/wjgo.v14.i8.1499
Figure 4 Gross pathology of the duodenum wall after irreversible electroporation.
A: The duodenal wall deepened in color with local congestion and edema 1 h after irreversible electroporation (IRE); B: Postoperative adhesion was observed 24 h after IRE without gastroduodenal obstruction; C and D: The duodenum went back to normal at 1 and 4 wk post-IRE.
- Citation: Yan L, Liang B, Feng J, Zhang HY, Chang HS, Liu B, Chen YL. Safety and feasibility of irreversible electroporation for the pancreatic head in a porcine model. World J Gastrointest Oncol 2022; 14(8): 1499-1509
- URL: https://www.wjgnet.com/1948-5204/full/v14/i8/1499.htm
- DOI: https://dx.doi.org/10.4251/wjgo.v14.i8.1499