Ref. | Study design | Needle | Passes | Specimen length (median) | Complete portal tracts (median) | Histological diagnosis |
DeWitt et al[8] | Prospective unicentre study n = 21 | Quick-Core1 | 1-4 | 9 mm | 2 | 71% |
Diehl et al[11] | Prospective multicentre study n = 110 | 19G (FNA) Expect1 | 1-2 | 38 mm | 14 | 98% |
Stavropoulos et al[10] | Prospective unicentre study n = 22 | 19G (FNA) Echotip2 | 1-3 | 36.9 mm | 9 | 91% |
Sey et al[9] | Prospective unicentre study n = 75 | Quick-Core1 | 1-7 | 9 mm | 2 | 73% |
ProCore 19G1 | 1-3 | 20 mm | 5 | 97% |