Table 3 Results of lumen-apposing metal stent placement
Proximal esophagus(n = 5) | Distal esophagus(n = 4) | Stomach(n = 6) | Duodenum(n =4) | Colon(n = 2) | Total(n = 21) | |
LAMS | ||||||
15 mm × 10 mm AXIOS | 5 (100.0) | 2 (50.0) | 3 (50.0) | 4 (100.0) | 2 (100) | 16 (76.2) |
10 mm × 10 mm AXIOS | 2 (33.3) | 2 (9.5) | ||||
16 mm × 30 mm NAGI | 2 (50.0) | 1 (16.7) | 3 (14.3) | |||
Mean stent dwell time (d) | 67.6 | 56.5 | 151.2 | 167.5 | 55.5 | 107.2 |
Technical success | 5 (100.0) | 4 (100.0) | 6 (100.0) | 4 (100.0) | 2 (100) | 21 (100.0) |
Clinical success | 11 | |||||
Short-term | 5 (100.0) | 3 (75.0) | 5 (83.3) | 4 (100.0) | 2 (100) | 19 (90.5) |
Long-term | 1 (25.0) | 2 (66.7) | 5 (100.0) | 3 (75.0) | 1 (50.0) | 212 (66.7) |
Reasons for stent removal | ||||||
Angulation | 1 | 1 | 2 | |||
Stent migration | 1 | 1 | 2 | 4 | ||
Stricture overgrowth | 2 | 1 | 2 | |||
Ulceration | 1 | 1 | ||||
Resolution | 1 | 11 | 3 | |||
Treatments after stent failure | ||||||
Balloon dilation | 2 | 2 | ||||
cSEMS | 1 | 1 | ||||
15 mm × 10 mm AXIOS | 1 | 1 | 1 | 3 | ||
16 mm × 30 mm NAGI | 2 | 1 | 3 |