Table 1 Summary of prior studies on lumen-apposing metal stent for benign strictures n (%)
Majumder et al[11] (2015) | Irani et al[12] (2016) | Yang et al[13] (2017) | |
Total cases | 5 | 25 | 30 |
Age | 47.4 (mean) | 54 yr (median) | 51.6 (mean) |
Females | 4 (80.0) | 18 (72.0) | 19 (63.3) |
Underwent prior endoscopic dilation | 3 (60.0) | 20 (80.0) | 27 (90.0) |
Prior cSEMS | 1 (20.0) | 1 (4.0) | 8 (29.6) |
LAMS used | |||
AXIOS 15 mm × 10 mm | 5 (100.0) | 25 (100.0) | 29 (96.7) |
AXIOS 10 mm × 10 mm | 0 | 3 (12.0)1 | 1 (3.3) |
Technical success | Not described | 25 (100)2 | 29 (96.7)3 |
Clinical success | Not described | ||
Short-term | 15 (60)4 | 27 (90.0)5 | |
Long-term | 19 (82.6)6 | ||
Migration | 0 | 2 (7.0) | 2 (8.0) |
Median stent dwell time (range) | Not described | 92 d (3-273, median) | Not described |
Median follow-up, d (range) | 120 (84-140) | 301 (62-681) | 100 (60-139) |
- Citation: Santos-Fernandez J, Paiji C, Shakhatreh M, Becerro-Gonzalez I, Sanchez-Ocana R, Yeaton P, Samarasena J, Perez-Miranda M. Lumen-apposing metal stents for benign gastrointestinal tract strictures: An international multicenter experience. World J Gastrointest Endosc 2017; 9(12): 571-578
- URL: https://www.wjgnet.com/1948-5190/full/v9/i12/571.htm
- DOI: https://dx.doi.org/10.4253/wjge.v9.i12.571