Copyright
©The Author(s) 2015.
World J Gastrointest Endosc. Jul 10, 2015; 7(8): 824-829
Published online Jul 10, 2015. doi: 10.4253/wjge.v7.i8.824
Published online Jul 10, 2015. doi: 10.4253/wjge.v7.i8.824
Method of excision | Number of polyps | Mean endoscopist’s estimate | Mean pathologist’s measurement | Mean difference | Overestimate | P value |
Biopsy excision | 52 | 0.54 (± 0.16) cm | 0.38 (± 0.19) cm | 0.16 cm | 39% | < 0.001 |
Snare polypectomy | 59 | 0.97 (± 0.34) cm | 0.54 (± 0.24) cm | 0.43 cm | 77% | < 0.001 |
Total | 111 | 0.76 (± 0.35) cm | 0.46 (± 0.23) cm | 0.3 cm | 65% | < 0.001 |
- Citation: Izzy M, Virk MA, Saund A, Tejada J, Kargoli F, Anand S. Accuracy of endoscopists’ estimate of polyp size: A continuous dilemma. World J Gastrointest Endosc 2015; 7(8): 824-829
- URL: https://www.wjgnet.com/1948-5190/full/v7/i8/824.htm
- DOI: https://dx.doi.org/10.4253/wjge.v7.i8.824