Table 4 Endoscopic ultrasound accuracy of T and N stage of rectal cancer
Ref.Ptsno.TStageNStageP/RTipe of EUS probe
Saitoh et al[13]8890%75%-Flexible, radial, (7 MHz) Rigid, radial (5-7.5 MHz)
Feifel et al[14]7989%-PRigid, linear (3-7 MHz)
Yamashita et al[15]12278%-RRigid, linear (5.5-7 MHz)
Beynon et al[16]10093%83%-Rigid
Rifkin et al[17]10272%81%Rigid, radial (7 MHz)
Hildebrandt et al[18]113-78%PRigid, radial (7 MHz)
Tio et al[19]9188%--Rigid
Katsura et al[20]12092%-Rigid, radial, (7 MHz)
Glaser et al[21]15486%81%PRigid, radial (7 MHz)
Herzog et al[22]11889%80%PRigid, radial (7 MHz)
Cho et al[23]7682%70%PFlexible, radial (7 MHz)
Thaler et al[24]3688%80%PRotating wall transducer IR 1510 AKTM (Kretz) (5, 7.5, 10 MHz)
Nielson et al[25]10085%--Probe (7 MHz)
Sailer et al[26]16077%83%PRigid
Nishimori et al[27]7076%69%Flexible
Norton et al[28]12192%65%PFlexible, radial (7.5-12 MHz)
Kim et al[29]8981%63%Rotating transducer (7.5 MHz)
Marone et al[30]6381%70%RFlexible, radial (7.5-12 MHz)
Akasu et al[31]15496%72%RFlexible, radial (7.5-12 MHz
Garcia-Aquilar et al[32]54569%64%PRigid, radial (7-10 MHz)
Harewood et al[12]8091%82%PFlexible, radial (7.5-12 MHz)
Marusch et al[33]42263%-PRigid
Kauer et al[34]45869%68%RProbe (7.5-10 MHz )
Vila et al[35]12083%72%PFlexible, radial
Landman et al[36]938-70%PProbe (10 MHz)
Halefoglu et al[37]3485%76%PProbe (7-10 MHz)
Lin et al[38]19286%78%PFlexible, radial (7.5-12 MHz)
Fernández-Esparrach et al[39]9095%65%PFlexible, radial (5-20 MHz)
Ünsal et al[40]3180%70%RRadial
Zhu et al[41]11091%85%-Rigid, radial (5-10 MHz)
4976
Mean8474
Range63-9663-85