Test person | Competence | Total colonoscopies | Colonoscopies in last year | Z mean | Z-score passed | Cecal intubation |
1 | Experienced Endoscopist | 3000 | 300 | 1.15 | Yes | Yes |
2 | Experienced endoscopist | 400 | 10 | 1.32 | Yes | Yes |
3 | Experienced endoscopist | 2000 | 0 | 1.25 | Yes | Yes |
4 | Experienced endoscopist | 1000 | 17 | 0.08 | Yes | Yes |
5 | Experienced endoscopist | 1700 | 150 | 0.30 | Yes | Yes |
6 | Experienced endoscopist | 4000 | 232 | 0.70 | Yes | Yes |
7 | Experienced endoscopist | 3000 | 14 | 0.78 | Yes | Yes |
8 | Experienced endoscopist | 2000 | 450 | 0.76 | Yes | Yes |
9 | Experienced endoscopist | 2000 | 75 | 0.82 | Yes | Yes |
10 | Experienced endoscopist | 350 | 30 | 0.73 | Yes | Yes |
11 | Novice | 0 | 0 | 1.54 | No | No |
12 | Novice | 0 | 0 | 1.48 | Yes | No |
13 | Novice | 0 | 0 | 1.28 | Yes | Yes |
14 | Novice | 0 | 0 | 2.26 | No | Yes |
15 | Novice | 1 | 1 | 6.19 | No | Yes |
16 | Novice | 0 | 0 | 0.27 | Yes | Yes |
17 | Novice | 0 | 0 | 6.50 | No | No |
18 | Novice | 0 | 0 | 5.25 | No | Yes |
19 | Novice | 0 | 0 | 1.17 | Yes | No |
20 | Novice | 0 | 0 | 3.25 | No | Yes |
21 | Novice | 2 | 2 | 0.65 | Yes | No |
- Citation: Svendsen MB, Preisler L, Hillingsoe JG, Svendsen LB, Konge L. Using motion capture to assess colonoscopy experience level. World J Gastrointest Endosc 2014; 6(5): 193-199
- URL: https://www.wjgnet.com/1948-5190/full/v6/i5/193.htm
- DOI: https://dx.doi.org/10.4253/wjge.v6.i5.193